Pci-7344. 1 before, and it is really weird. Pci-7344

 
1 before, and it is really weirdPci-7344  Return to Home Page; Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver

. Sorry but I can't give you any further help. 25 ms to 1. Re: PCI/FW-7344 Motion controller either isn't found or when it is, MAX crashes depending on which version of NI-Motion, DAQ and. To guarantee the delay-free commands flow we use the programmable FPGA device present on the NI-Motion PCI-7344 stage controller board. 25 ms to 1. Should I setup my limit switches to stop the axis at the limit and then reset encoders there or what? Or should I have a home switch somewhere in the center of travel and let Labview reset the encoders at. Industries. 4>—The 7344/7334 controller includes an eight channel multiplexed, 12-bit ADC capable of measuring ±10 V, ±5 V, 0–10 V, and 0–5 V inputs. 0 and PCI-7344 motor. 4-Axis, Stepper PXI Motion Controller Module—The PXI‑7334 is designed for point‑to‑point motion applications. But the MAX couldn't read the current traject. 1. 8. can we get the VI for oscillator with variable frequency from 10 khz to 1 Mhz with variable duty cycle. I am using four amplifiers; three are on linear motors, one on a ball screw. 配置您的步进器设置. used. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. . In the Details tab, when selecting the "Device instance path" or "Hardware Ids" Property, there should be an entry similar to PCIVEN_XXXX&DEV_XXXX&. PCI-7344. 4-Axis, Stepper/Servo Motion Controller DeviceNI PCI 7344 motion controller was used for controlling the four motors. . 1) How do i know if this motor drive is compatible with the pci-7344 and umi7774 ? for example: inside the UMI manual is written that the Motor drive must support "Sinusoidal Commutation" i. Hardware Using the existing Rhino Robotics Ltd. I am using a PCI-7344 card with LabView to control a 3-axis servo motor motion system in conjunction with a data acquisition system. また、NIのホームパージから. I. Thank you for your reply !! I am developing pci-7344`s driver under venturecom`s rtx,now I have found the baseadresses[0] and baseadresses[1] . the PCI-7344 can control up to four axes. 240 MHz signal. Thank you. You won't be able to achieve these types of signals with a 7344 motion control board. Now i want a window in my Front Panel that will show me in which layer/face the machine is working/moving. We have just recently switched to a new hardware revision and now all boards don't show up with their specific names but with the name of the board family: Board Family Specific Boards. Worldwide Technical Support and Product Information National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100The PCI-7344, PXI-7344, PCI-7334, and PXI-7334 controllers are fully compatible with the PCI Local Bus Specification, Revision 2. Re: Position Control of compumotor linear servo table and GV-U6E with PCI-7344. This controller is able to achieve simultaneous three-axis motion trajectories through linear, spherical, circular or helical interpolation, which will placate all our requirements for concurrent three-axis machining and also for the FDM operation. Dennis_Knutson. com FREE DELIVERY possible on eligible purchasesI'm using a PCI-7344 with an MD7506 motor driver from RS. Options. When i try to autotune, the servo motor goes berserk, so I have to manually tune it with "Step response". Product Manuals: 7344/7334 Hardware User Manual Products & Services: National Instruments Motion Control NI Motion: Users Manual 附件: 报告日期: 10/03/2002 最近更. It is related to 3D printer. eBay item number: 293975447283. I am already using one. Please. 2: I wrote an onboard program that makes a 2axis move and one/two onboard program(s) that write with HighSpeedCapture the Positions to a buffer. Mid-Range Stepper/Servo Motion Controllers 2 AMC GmbH Chemnitz * Tel: 0371/38388-0 * Fax: 0371/38388-99 * [email protected] PCI-7344 with LabView for use as a Parabolic Antenna controller. Since, I'm waiting in a loop for the Move Complete bit, the program (VB 6. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or. actually the program has. flx) to trigger a move (Start Motion. -While controlling the motors in the "Interactive control" tab, the position. rules. 14 PC-Based System with FP 2000 Hardware Configurations 42. A much better choice is the use of a motion control board, e. 付属されていた新しいドライバCDはインストールしましたでしょうか?. Any help is appreciate. lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. 2 + NI motion 7. The 7342 follows this position profile using a spline algorithm. There was a "broken" device PCI-7344 under NI Motion Devices, which status said something like "This device has been removed or could not be detected" and the Res. 20. 17) before running VI. 1 before, and it is really weird. I've never used LabVIEW 6. To research general control behavior this might be ok but if you want to use FieldPoint in a real-world application you should figure out if the PID loop is fast enough for you. Martin Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. 展开 设备和接口 树. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Member ‎08-12-2003 06:30 PM. 8 degree pitch (200 steps per rev). While this is happening, I need to change the velocity of one of the motors. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. flx, but i don't know how to wire it. Hi, I updated my PCI-7344 + LabView 7. 2 version but I can't be initialize the motion card in MAXDiscontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. Order toll free: 800. In my VI, I have called the Enable Limits. 我用的松下的伺服电机和松下的伺服驱动,原来我用plc控制实现单轴移动,现在我想用umi- 7764和pci-7344 实现对电机控制. Re: PCI-7344 motor interfacing help. vi". MPN. i found. Use a lower resolution stepper motor. Page 1 PXI-7344. The Motion driver with the PCI 7344 has its own algorithm in place. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The feedforward gain of velocity loop is determined by the timing range and the feedback gain of po. Is it possible to use the PCI-7344 board. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. Especially, the hardware upgrade option is something great. Please refer to the contouring examples shipping with LabVIEW. In the second part, you. The analog signal can be from -10 to 10V. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. National Instruments PCI-7344. am rules/80-net-setup-link. Page 2 Motion Control 7344/7334 Hardware User Manual 7344/7334 Hardware User Manual May 2001 Edition Part Number 322504B-01. 0 Kudos Message 1 of 7 (4,209 Views) Reply. the drive feeds back a simulated. STL file there are 28 layers/faces. (67 pages) Controller National Instruments 7932 Manual. 3008 to 7. But when it comes to the analog output from UMI7774, i can't measure any signal from there while i am sending commands from. I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. Knight of NI. Go to the Axis Configuration option, under the desired axis (e. Single-board rio oem devices (50 pages) The PCI-7344 is not a working device but something I created to explore the change board ID option. I have tried, but the outcome always changes the sharp corners into round corners with excessive r values. Hello, I really really need help in this: I have UMI 7774 and PCI 7344 and i have problems to Connect it to my Servo Motor Drive. We facilitated the wiring of inputs to each of these components with NI SCB-68 digital I/O connector block and the UMI-7764 motion interface. Shut down your computer. Hi, I am using a PCI-7344 with a UMI-7764 to try and control 3 linear actuators and 1 semi-rotary actuator, each of these actuators takes a 0-10v dc voltage and has a feedback signal of 0-10v dc, both input and output being proportional to linear/angular displacement. Axis 4 is used with encoder 2 as the primary feedback. Please. This warranty includes parts and labor. Manufacturer: National Instruments. There are no. But i >want to do it automatically in a VI. . 6: Cấu trúc của máy phay CNC. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. So I wonder if there is driver u. Return to Home Page; Toggle navigation; Solutions. No worries Chris. 1) I successfully tuned the PID parameters so all the 4 motors are servoing now. PCI-7344を他社製のモータードライバに接続しようと思います。モータードライバのパルス入力の仕様で、パルス幅が10μSec以上となっているのですが、PCI-7344を接続して使うことはできますか?Using a PCI 7344 and three servos (with LabVIEW). g. Save on shipping. After the update the card was not anymore detected in MAX. 08-10-2007 01:26 AM. Starting on page 5-9. 8. 579 views 3 years ago. 0 and earlier. Trusted Seller. When the button is pressed, PCI-7344's shutdown input (pin 62) will be grounded. The indexes are offset from each other. . 00 +$12. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. pci-7340 initialization problem mechanical Engineer. All of 3 motors require +5V 24mA for the Mike encoder. Options. The change was part of an improvement to the manufacturing process for. Find many great new & used options and get the best deals for National Instruments PCI-7344 Servo Controller Card at the best online prices at eBay! Free shipping for many products!Re: LabVIEWアップデートに伴うPCI-7344のエラー. activate the INH output via software. Motion control (52 pages) Controller National Instruments 7344 Series User Manual. . Try searching for what you need. 32. 75 ms. I am not creating an installer for the program and I am trying to run it on the same machine that has the development environment. I continue to get more and more modal errors from the board. 2. Problem 1 The encoder counts up and down ok but gives 4096 counts between z pulses and not 1024. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. In our system, a high resolution encoder works as the feedback sensor, and a third-party of servo works as the velocity loop controller. Under windows system I use the flexmotion32. 0. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. When calling "DIO Port Config. Tie rod must be vibrated by linear servo hydraulic. (67 pages) Controller National Instruments sbRIO-9607 User Manual. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. Options. WindowsXP system put it as unknown PXI-4200 board. The PCI‑7344 also provides contouring capability for complex moves. Due to synchronization constraints I need hardware scanning synchronized with some internal clock instead of software scanning using a set. You willI have a E-Stop button on my machine. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Options. I am a Master’s student of International Islamic University Malaysia. 2. So i am just wondering if the SCB-68 can be used as the ter. For my research purpose I need some important information from you. NI 7350 NI 7352, NI 7354, NI 7356, NI 7358. I am usi. . An introduction to the National Instruments PCI-7344 Motion Controller Featured with 3D contouring, 3D linear and. Lực cắt tham chiếu CNC FANUC Máy tính 2 + Phần mềm hiển thi (DASYLab)+ Điều khiển thích nghi Q trình phay Lượng chạy dao Card điều khiển Flexmotion PCI - 7344 Máy tính 1 + CNC Controller Card PCL -812PG Điều chỉnh lượng chạy dao Luợng chạy dao Lực kế Hình 1. We are configuring a new closed loop stepper setup with PCI 7344 and the "Trigger Input occurred" led in MAX is turning red after a search for encoder index. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 01-30-2006 10:29 AM. . The reason for the 64-bit operation is a 3rd party function generator card that requires 64-bit LabView to work in conjunction with the 64-bit drivers. 展开 PCI-73xx 树. i finally start to understand the setting after i read the PCI7390 which is position-comannd controller. BUT, i though that the pci-7344, and the umi-7774 that i have should handle ALL the operations i need to drive the servo. 1 (NIMotion7. Servo motors expect a pulse every . The Problem is feedback from each axis (AZ & EL). If you need a specific firmware or series relating to PCI-7344, we probably have it. Now I have used to VI PWm duty and config PWM. The intent is to collect data at each grid point of an X-Y grid. The onboard CPU uses an embedded real-time OS. The 7334 controllersThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. . FlexMotion 5. Best regards, Jochen Klier. Configure your stepper settings. The step/ direction signals from the controller card are converted to phase-drive signals using three UCN5804B stepper ICs, one for each axis, and routed through a 25-pin D-subminiature connector cable to the MAXNC-10. 1) When I am stationary and command a Halt, there is a resulting jerk movement, sometimes up to a few 1000 servo steps. In our normal system, we use 16 or 12 bit S/. Hi, Is there any body to have controlled torque with PCI-7344? I have two servos to keep servo's torque constant as a target value. In the second part, you program for the PCI-7344 controller, which adds several advanced features including the ability to run onboard programs. . I've got a PCI card (PCI 7344 for motion control). 2. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. vi as a starting point, I programmed my data acquisition vi to start when the Check Blend Complete. Cary, NC,. vi twice for both the Hardware and Software limits. Sadiah, please note that FieldPoint is much slower than a PCI-7344. 3. I have been using a PCI-7344 (driven by NI Motion 5. My email id is sy. 0. item 5 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 $500. A National Instruments PCI-7344 4-axis controller card that resides in a PCI slot in a Windows PC controls motion. At Lektronix we can provide you with a brand new National Instruments PCI-7344 covered by the Original Manufacturers Warranty. 3. It is very likely that you will not be able to simulate the FW-7344 controller in MAX, due to these limitations. used. Using the X-Y Grid Inspection (Template). The onboard CPU uses an embedded real-time OS. Options. Remote Printing. However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. 0. . something) Thanks - raymond. If you are upgrading from a previousNI Product Documentation Center. But to my surprise the output is not matching the required data. The marking triggering signal (TTL) generated by a rotary encoder is applied to the trigger input of the NI-MID 7604 module trough a delay circuit (2) and a logic gate (AND) of SPUC. the PCI-7344 or PCI-7342 board. The machineGood afternoon, I'm using servomotors PSKF321 (SEW) and servodrives MDX61B (SEW). PCI-7344 PCL812PG TRỤC CHÍNH BÀN MÁY CHI TIẾT LỰC KẾ Hình 1. . i just need to know if what i write here is correct. The 7334 controllersHello, We are planning to build a tie rod fatigue test system with Labview and NI PCI-7344 4-Axis Motion Control Board. The 7334 controllers are exclusively stepper motor controllers. Because of the reason mentionned in the link in my first mail, I doubt that a calibration certificate exists for this card. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100PCI-7344, 4-Axis, Motion Controller National Instruments PCI-7344 Motion Controller DeviceFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Inst. Ca hai ho tr ay u viec lap trnh ieu khien chuyen ong cho phep ieu khien toi a 4 truc ong thi va oc lap. As LabVIEW is widely used to control devices through standardized communication interfaces like RS232 or GPIB, there is a chance, that the. 6: Cấu trúc của máy phay CNC. The fact is ,as most say,the driver is not suitable under non-windows systems. Re: LabVIEWアップデートに伴うPCI-7344のエラー. Additionally it incorporates LabVIEW RT and LabVIEW FPGA programming. The pulse should last from 1. Hi, I use PCI-7344 and UMI-7764 and upgrade the motion software and firmware to 7. After the update the card was not anymore detected in MAX. Is it possible to realize such a sample rate with breakpoints and an onboard program like: "Modulus Breakpoint (on-board re-enable). The capture method is configurable. -While controlling the motors in the "Interactive control" tab, the position. The 10 ms timing for contoured move is the fastest that you can get out of the board. My DAQ is set as device 2 and my motion controller is set as board 1. PCI-7344. The 3 axes operate together in contouring mode. Please let me know if you have any additional questions on this issue. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Under windows system I use the flexmotion32. Cac cong I/O c tch hp san nh cac cong tac gii han hanh trnh, cac cong tac ho tr cho viec thiet lap goc toa o (Set home) may va mot so cho cac muc ch chung khac. JB. Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Instruments PCI-7344 (Part number: 778916-04) is a high-quality Motion Controller for stepper/servo control applications. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. MAX 5. I've created a program that uses motion control and digital I/O via the PCI-7344 Motion Control card. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 [email protected] there, I would like to trigger my piezoelectric motor more than 100Hz, can I do that with motion controller PCI-7344/PCI-6036E and using while Return to Home Page Toggle navigationThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. However, when the Software limits are reached, the. It includes two processors and a real-time on-board system, and has multi axis insertion function. I am using axis 3 with encoder 1 as the primary feedback, and as the control output. 3-Axis control, stepper motors, closed loop with optical linear encoders. NI 7340 NI 7342, NI 7344. There are three cards PCI-7344 with the same behavior. This is a troubleshooting challenge. PCI 7344 card. Fast Quotes & Shipping. My pr. Hi, I am running a motor using the PCI 7344 motion control board and a MID-7654 servo with encoder feedback. 客户使用pci-7344,umi-7764连接第三方的电机和驱动器,搭建了一个闭环控制系统,但发觉电机编码器反馈回的值有些问题. Mark as New; Bookmark. Right now I have completed the wiring of feedback from motor encoder and managed to see encoder readings in MAX. The VIs send motion commands to the board and also monitor the position of the axis. I. Send documents to the printer connected to your host computer or to the printer connected to the computer you are. The Stepper Motors on My machine don't move on my machine, I have PCI -7344 card connected to UMI 7764 with 68 pin connector. T. I have verified the connection is working. To perform a simple move in Measurement and Automation (MAX) is very simple. Feel free to check it out here. 付属されていた新しいドライバCDはインストールしましたでしょうか?. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. This warranty includes parts and. I recently upgraded to MAX version 2. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. If you are upgrading from a previousI am using PCI7344 and UMI7774 to do simple control of a motor to make certain movements. I am using a PCI-7344 motion controller to control a slide and motor system. Order international: +1 609. Seller assumes all responsibility for this listing. Options. Cary, NC, USA. 5f1. If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. Regards, Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). 10. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. g. 付属されていた新しいドライバCDはインストールしましたでしょうか?. [systemd-commits] hwdb/20-OUI. 12 PCI 7344 MAX -Two-axis Configurations 39 3. supoose in my . Member. I´m develop an automated platform by means of stepper motors using the PCI 7344 board and the MID-7604. Re: problems with a PCI-7344 motion controller. I am using the PCI-MIO-16XE-50 and PCI-7344. Options. For my research purpose I need some important information from you. If yes, then how to configure the other one, so. Warranty Terms and Conditions. After un-installing all NI software I now find that I cannot get the system to recognize the PCI-7344 board. 0 Kudos Message 1 of 4 (2,952 Views) Reply. 0) hangs. I initialise it using NI MAX (version 2. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. 09-27-2002 08:03 AM. I have a software controlling 4 servo motors using PCI 7344,UMI7764 and NI-motion 14. It is related to 3D printer. Re: PCI-7344 motor interfacing help. Periodically the servo system does not work. I'm stepping the motor round by one step, checking that it's got there by reading the encoder, measuring the sensor voltage and repeating. It breaks out the signals available from the PCI-7344. 75 ms. PCI-7344, 4-Axis, Motion Controller National Instruments PCI-7344 Motion Controller DeviceFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Inst. This means you can create a position profile and download these contouring data to the PCI-7342. If you have non-plug and play (ISA bus) boards, refer to the ISA Installation (PC-FlexMotion-6C Only) section of this document. Chapter 5 Signal Connections Analog Inputs The 7344/7334 controller has the following ADC input signals: • 7344/7334 Hardware User Manual Analog Input <1. Unfortunately my FW-7344 has malfunctioned and my supervisor has asked me to research other options to have it replaced. The parameters of that algorithm can be modified, but the algorithm itself is fixed. Looking to measure speeds up to 500 RPM. But when it comes to the analog output from UMI7774, i can't measure any signal from there while i am sending commands from. . No worries Chris. Solution. I'm using the PCI-7344/UMI-7764 to control the motors. Using PCI-7344 and MID-7604 and FLEXMOTION. . 5,控制方式采用的是位置控制模式. The 10 ms timing for contoured move is the fastest that you can get out of the board. The PCI‑7344 also provides contouring capability for complex moves. Hello, I am using a PCI-7344 motion controller card to drive 2 stepper motors in closed loop mode. The PCI 7340 (4 axis) board is a drop in replacement for the PCI-7344. It's very dangerous,my compents are allways hit. 0 and NI-Motion 7. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. The intent is to collect data at each grid point of an X-Y grid. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The NI 73xx Motion Controllers use the NI-Motion drivers, and do not appear to support IVI (necessary to use Instrument Control toolbox) or NI-DAQmx (necessary for access from Data Acquisition toolbox). PCI-7344 National Instruments PCI-7344 National Instruments Module Clips Drive controller servo motor Contact: Mr. You can select certain frequencies for the PWM which correspond to the divided down 10. 0 and earlier. Hi all, I'm using the PCI-7344 board and I'd like to trigger an external device. 1. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. . The Problem is feedback from each axis (AZ & EL). I am using Acquire Trajectory Data. NI 7350 NI 7352, NI 7354, NI 7356, NI 7358. 4-Axis, Stepper/Servo Motion Controller Device4-Axis, Stepper/Servo PXI Motion Controller Module —The PXI‑7344 is recommended for both simple and complex motion applications. Shut down your computer. 2. 能否用NI运动控制卡读取非正交编码器? 硬件: Motion Control>>Controllers>>PCI-7344, Motion Control>>Controllers>>PXI-7344, Motion Control. All the best-John 05-14-2002 08:10 AM. 09-27-2002 08:03 AM. 1) connected to a MID-7604 drive to control three IDC P21T stepper motors. com FlexMotion Software Installation Install the FlexMotion software before installing a FlexMotion series motion controller for the first time. Right-click on PCI Device and select Uninstall. It offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high. I am having some trouble indexing an axis on our PCI-7344 card. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. 1 were installed. Hello everyone I am using the PCI 7344 card. The Hardware limits work as expected.